Neutrophil Gelatinase-Associated Lipocalin (NGAL) (human) Elisa Kit Early Diagnosis of Acute Kidney Injury

Products

HomeHome / Products / ELISA Kit / Details
Neutrophil Gelatinase-Associated Lipocalin (NGAL) (human) Elisa Kit Early Diagnosis of Acute Kidney Injury

Neutrophil Gelatinase-Associated Lipocalin (NGAL) (human) Elisa Kit Early Diagnosis of Acute Kidney Injury

Overview Neutrophil Gelatinase-Associated Lipocalin (NGAL) (human) Elisa Kit Early Diagnosis of Acute Kidney Injury Prod

Send your inquiry

DESCRIPTION

Basic Info
Model NO. NGAL
Type Test Strips & Test Tube
Material Elisa Kit
Ethylene Oxide Sterilization Without Ethylene Oxide Sterilization
Quality Guarantee Period Two Years
Group Adult
Function Early Diagnosis of Acute Kidney Injury
Company Manufacture
Transport Package Color Box
Specification 50pcs/box
Trademark Singclean
Origin China
Product Description

Neutrophil Gelatinase-Associated Lipocalin (NGAL) (human) Elisa Kit Early Diagnosis of Acute Kidney Injury

Product Description

The NGAL Test™ is a particle-enhanced turbidimetric immunoassay for the quantitative determination of neutrophil gelatinase-associated lipocalin (NGAL) in human urine, EDTA plasma or heparin plasma on automated clinical chemistry analyzers. NGAL measurements are useful in the diagnosis of acute kidney injury which may lead to acute renal failure. One Step Test for NGAL (Colloidal Gold) applies colloidal gold Immunol Chromatography, for the qualitative detection of Neutrophils Gelatinase Associated Lipocalin (NGAL) in human urine specimen. This test is used as an aid in the early diagnosis of acute kidney injury, risk classification and treatment monitoring.Assay specifications

MethodParticle-enhanced turbidimetric immunoassay (PETIA)
SampleUrine, heparin and EDTA plasma
Number of testsApprox. 100 (Can vary based on analyzer model)
Assay timeApprox. 10 minutes
Measuring range25 to 5,000 ng/mL
Shelf life24 months from manufacturing. See expiry date on the label
Stability after opening4 weeks at 2-8°C. On the Hitachi 917 analyzer, the manufacturer obtains satisfactory performance for up to 8 weeks.
On board stability4 weeks at correct temperature (2-8°C) in appropriate containers. On the Hitachi 917 analyzer, the manufacturer obtains satisfactory performance for up to 8 weeks on board
Sample stabilityIf testing after 24 hours of sampling, freeze samples at -20°C or below. For long-term storage of specimens, -70°C or below is recommended
ApplicationIVD - in vitro diagnostic use*

Assay procedure

The assay should be carried out in accordance with the specific application note for the chemistry analyzer to be used.

Clinical application

Measuring NGAL in urine or plasma gives you information on AKI status that you need for rapid decision making e.g. in the following settings -

  • Intensive care - monitoring
  • Emergency room - triage tool
  • Cardiopulmonary bypass surgey - monitoring
  • Renal transplantation - predictive evaluation
  • Intravenous contrast agents - assessing nephrotoxicity

Method patented/patent pending in selected countries. FEATURES

High sensitivity: 10ng/mlHigh accuracy: 98%Wide linear range:5-300ng/mlSmall sample size:5ul(urine)STORAGEOriginal packaging should be stored in the 4-30 ºC, a cool, dark, dry place, frozen is avoid.The period of validity: 24 months.