Neutrophil Gelatinase-Associated Lipocalin (NGAL) (human) Elisa Kit Early Diagnosis of Acute Kidney Injury
Overview Neutrophil Gelatinase-Associated Lipocalin (NGAL) (human) Elisa Kit Early Diagnosis of Acute Kidney Injury Prod
Send your inquiryDESCRIPTION
Basic Info
Model NO. | NGAL |
Type | Test Strips & Test Tube |
Material | Elisa Kit |
Ethylene Oxide Sterilization | Without Ethylene Oxide Sterilization |
Quality Guarantee Period | Two Years |
Group | Adult |
Function | Early Diagnosis of Acute Kidney Injury |
Company | Manufacture |
Transport Package | Color Box |
Specification | 50pcs/box |
Trademark | Singclean |
Origin | China |
Product Description
Neutrophil Gelatinase-Associated Lipocalin (NGAL) (human) Elisa Kit Early Diagnosis of Acute Kidney Injury
Product Description
The NGAL Test™ is a particle-enhanced turbidimetric immunoassay for the quantitative determination of neutrophil gelatinase-associated lipocalin (NGAL) in human urine, EDTA plasma or heparin plasma on automated clinical chemistry analyzers. NGAL measurements are useful in the diagnosis of acute kidney injury which may lead to acute renal failure. One Step Test for NGAL (Colloidal Gold) applies colloidal gold Immunol Chromatography, for the qualitative detection of Neutrophils Gelatinase Associated Lipocalin (NGAL) in human urine specimen. This test is used as an aid in the early diagnosis of acute kidney injury, risk classification and treatment monitoring.Assay specifications
Method | Particle-enhanced turbidimetric immunoassay (PETIA) |
---|---|
Sample | Urine, heparin and EDTA plasma |
Number of tests | Approx. 100 (Can vary based on analyzer model) |
Assay time | Approx. 10 minutes |
Measuring range | 25 to 5,000 ng/mL |
Shelf life | 24 months from manufacturing. See expiry date on the label |
Stability after opening | 4 weeks at 2-8°C. On the Hitachi 917 analyzer, the manufacturer obtains satisfactory performance for up to 8 weeks. |
On board stability | 4 weeks at correct temperature (2-8°C) in appropriate containers. On the Hitachi 917 analyzer, the manufacturer obtains satisfactory performance for up to 8 weeks on board |
Sample stability | If testing after 24 hours of sampling, freeze samples at -20°C or below. For long-term storage of specimens, -70°C or below is recommended |
Application | IVD - in vitro diagnostic use* |
Assay procedure
The assay should be carried out in accordance with the specific application note for the chemistry analyzer to be used.
Clinical application
Measuring NGAL in urine or plasma gives you information on AKI status that you need for rapid decision making e.g. in the following settings -
- Intensive care - monitoring
- Emergency room - triage tool
- Cardiopulmonary bypass surgey - monitoring
- Renal transplantation - predictive evaluation
- Intravenous contrast agents - assessing nephrotoxicity
Method patented/patent pending in selected countries. FEATURES
High sensitivity: 10ng/mlHigh accuracy: 98%Wide linear range:5-300ng/mlSmall sample size:5ul(urine)STORAGEOriginal packaging should be stored in the 4-30 ºC, a cool, dark, dry place, frozen is avoid.The period of validity: 24 months.
Detailed Photos
Main Products
Company Profile
Related Products
-
Factory Price High Purity 99% Medicine Grade Epo Powder
-
Herbway Echinacea Purpurea Extract, Best Price, Hot Sale Purple Coneflower, High Quality and High Efficiency Manufacturer, Supplier From China, Plant Extract
-
Recombinant Canine Thyroid Stimulating Hormone (TSH) Protein
-
Ribavirin Test Residue Elisa Kit for Tissues